倍加福安全栅现货特价销售KFD2-SR2-EX2.W
倍加福安全栅现货特价销售KFD2-SR2-EX2.W
产品价格:¥1(人民币)
  • 规格:KFD2-SR2-EX2.W
  • 发货地:上海
  • 品牌:
  • 最小起订量:1只
  • 诚信商家
    会员级别:钻石会员
    认证类型:企业认证
    企业证件:通过认证

    商铺名称:上海工午电气有限公司

    联系人:杨文远(先生)

    联系手机:

    固定电话:

    企业邮箱:yangwenyuan0202@163.com

    联系地址:上海市浦东新区自由贸易试验区301号

    邮编:200136

    联系我时,请说是在焊材网上看到的,谢谢!

    商品详情
      Release date  2012-07-06 08:53 Date of issue  2012-07-17 132960_eng.xml
      KFD2-SR2-Ex2.W
      Subject to reasonable modifications due to technical advances.  Copyright Pepperl+Fuchs, Printed in Germany
      Pepperl+Fuchs Group • Tel.: Germany +49-621-776-0 • USA +1-330-4253555 • Singapore +65-67-799091 • Internet www.pepperl-fuchs.com 1
      Switch Amplifier
      2+
      3-1+
      Zone 2
      Div. 2
      Zone 0, 1, 2
      Div. 1, 2
      KFD2-SR2-Ex2.W
      7
      8
      9
      10
      11
      12
      I
      II
      I
      II
      24 V DC
      14+
      15-Power Rail
      24 V DC ERR
      5+
      6-4+
      10 kΩ
      10 kΩ
      400  Ω ≤ R ≤ 2 k Ω
      10 kΩ
      10 kΩ
      400  Ω ≤ R ≤ 2 k Ω
      Connection
      Assembly
      • 2-channel isolated barrier
      • 24 V DC supply (Power Rail)
      • Dry contact or NAMUR inputs
      • Relay contact output
      • Line fault detection (LFD)
      • Reversible mode of operation
      • Up to SIL2 acc. to IEC 61508
      Function
      This isolated barrier is used for  intrinsic safety applications. It
      transfers digital signals (NAMUR sensors/mechanical
      contacts) from a hazardous area to a safe area.
      The proximity sensor or switch controls a form C changeover
      relay contact for the safe area load. The normal output state
      can be reversed using switches S1 and S2. Switch S3 is used
      to enable or disable line fault  detection of the field circuit.
      During an error condition, the relays revert to their de-energized state and the LEDs in dicate the fault according to
      NAMUR NE44.
      A unique collective error messaging feature is available when
      used with the Power Rail system.
      Features
      1 3
      4 6
      2
      5
      13 15
      12
      9
      10
      7
      14
      11
      8
      KFD2-SR2-Ex2.W
      1
      2
      OUT CHK PWR
      S2
      S1
      S3
      II I
      Front view
      LED yellow:
      Relay output  Ι
      LED red:
      LB/SC channel  Ι
      LED yellow:
      Relay output  ΙΙ
      LED red:
      LB/SC channel  ΙΙ
      Switch S3
      (LB/SC-monitoring)
      LED green:
      Power supply
      Removable terminals
      green
      Removable terminals
      blue
      Switch S1
      (Mode of operation channel  Ι)
      Switch S2
      (Mode of operation channel  ΙΙ )
      2
      Release date  2012-07-06 08:53 Date of issue  2012-07-17 132960_eng.xml
      Technical data KFD2-SR2-Ex2.W
      Subject to reasonable modifications due to technical advances.  Copyright Pepperl+Fuchs, Printed in Germany
      Pepperl+Fuchs Group • Tel.: Germany +49-621-776-0 • USA +1-330-4253555 • Singapore +65-67-799091 • Internet www.pepperl-fuchs.com 2
      General specifications
      Signal type  Digital Input
      Supply
      Connection  Power Rail or terminals 14+, 15-Rated voltage  20 ... 30 V DC
      Ripple  ≤  10  %
      Rated current  ≤  50 mA
      Power loss  1 W
      Power consumption  < 1.3 W
      Input
      Connection  terminals 1+, 2+, 3-; 4+, 5+, 6-Rated values  acc. to EN 60947-5-6 (NAMUR)
      Open circuit voltage/short-circuit current  approx. 8 V DC / approx. 8 mA
      Switching point/switching hysteresis  1.2 ... 2.1 mA / approx. 0.2 mA
      Line fault detection  breakage I  ≤ 0.1 mA , short-circuit I > 6 mA
      Pulse/Pause ratio  ≥  20 ms /  ≥  20 ms
      Output
      Connection  output I: terminals 7, 8, 9 ; output II: terminals 10, 11, 12
      Output I, II  signal, relay
      Minimum switch current  2 mA / 24 V DC
      Energized/De-energized delay  approx. 20 ms / approx. 20 ms
      Mechanical life  10
      7
       switching cycles
      Transfer characteristics
      Switching frequency  ≤  10 Hz
      Electrical isolation
      Input/Output  reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V
      eff
      Input/power supply  reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V
      eff
      Output/power supply  reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V
      eff
      Output/Output  reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V
      eff
      Directive conformity
      Electromagnetic compatibility  
      Directive 2004/108/EC  EN 61326-1:2006
      Low voltage  
      Directive 2006/95/EC  EN 61010-1:2010
      Conformity
      Electromagnetic compatibility  NE 21:2006
      Protection degree  IEC 60529:2001
      Input EN 60947-5-6:2000
      Ambient conditions
      Ambient temperature  -20 ... 60 °C (-4 ... 140 °F)
      Mechanical specifications
      Protection degree  IP20
      Mass  approx. 150 g
      Dimensions  20 x 119 x 115 mm (0.8 x 4.7 x 4.5 in) , housing type B2
      Mounting  on 35 mm DIN mounting rail acc. to EN 60715:2001
      Data for application in connection
      with Ex-areas
      EC-Type Examination Certificate  PTB 00 ATEX 2080 , for additional certificates see www.pepperl-fuchs.com
      Group, category, type of protection  ¬ II (1) G [Ex ia] IIC, II (1) D [Ex ia] IIIC
      Input  [Ex ia] IIC, [Ex ia] IIIC
      Voltage U
      o
       10.5 V
      Current I
      o
        13 mA
      Power P
      o
        34 mW (linear characteristic)
      Supply  
      Maximum safe voltage  U
      m
      253 V AC / 125 V DC (Attention! U
      m
       is no rated voltage.)
      Output  
      Contact loading  253 V AC/2 A/cos  φ  > 0.7; 126.5 V AC/4 A/cos  φ > 0.7; 40 V DC/2 A resistive load
      Maximum safe voltage  U
      m
      253 V AC (Attention! The rated voltage can be lower.)
      Statement of conformity  Pepperl+Fuchs
      Group, category, type of protection  ¬ II (3)G [Ex ic] IIC; [Ex nL] IIC
      Input  [Ex ic] IIC; [Ex nL] IIC
      Voltage U
      o
      10.5 V
      Current I
      o
      13 mA
      Power P
      o
      34 mW (linear characteristic)
      Release date  2012-07-06 08:53 Date of issue  2012-07-17 132960_eng.xml
      Technical data KFD2-SR2-Ex2.W
      Subject to reasonable modifications due to technical advances.  Copyright Pepperl+Fuchs, Printed in Germany
      Pepperl+Fuchs Group • Tel.: Germany +49-621-776-0 • USA +1-330-4253555 • Singapore +65-67-799091 • Internet www.pepperl-fuchs.com 3
      Output 
      Contact loading  253 V AC/2 A/cos φ  > 0.7; 126.5 V AC/4 A/cos  φ > 0.7; 40 V DC/2 A resistive load
      Statement of conformity  TÜV 99 ATEX 1493 X , observe statement of conformity
      Group, category, type of protection,
      temperature class
      ¬ II 3G Ex nA nC IIC T4
      Output 
      Contact loading  50 V AC/4 A/cos φ > 0.7; 40 V DC/2 A resistive load
      Electrical isolation  
      Input/Output  safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
      Input/power supply  safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
      Directive conformity  
      Directive 94/9/EC  EN 60079-0:2009, EN 60079-11:2007 , EN 60079-15:2005 , EN 61241-11:2006
      International approvals
      FM  approval  
      Control drawing  116-0035
      CSA approval  
      Control drawing  116-0047
      IECEx approval  IECEx PTB 11.0034
      Approved for  [Ex ia] IIC , [Ex ia] IIIC , [Ex ia] I
      General information
      Supplementary information  EC-Type Examination Certificate, Statement of Conf ormity, Declaration of Conformity, Attestation of
      Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
      Release date  2012-07-06 08:53 Date of issue  2012-07-17 132960_eng.xml
      Technical data KFD2-SR2-Ex2.W
      Subject to reasonable modifications due to technical advances.  Copyright Pepperl+Fuchs, Printed in Germany
      Pepperl+Fuchs Group • Tel.: Germany +49-621-776-0 • USA +1-330-4253555 • Singapore +65-67-799091 • Internet www.pepperl-fuchs.com 4
      Power feed module KFD2-EB2
      The power feed module is used to supply  the devices with 24 V DC via the Power Ra il. The fuse-protected power feed module
      can supply up to 150 individual devices depending on the power co nsumption of the devices. A galvanically isolated mechanical
      contact uses the Power Rail to transmit collective error messages.
      Power Rail UPR-03
      The Power Rail UPR-03 is a complete unit consisting of the electrical inset and an  aluminium profile rail 35 mm x 15 mm. To make
      electrical contact, the de vices are simply engaged.
      Profile Rail K-DUCT with Power Rail
      The profile rail K-DUCT is an aluminum profile rail with Power Ra il insert and two integral cable ducts for system and field cab les.
      Due to this assembly no additional cable guides are necessary.
      Power Rail and Profile Rail must not be fed via the device terminals of the individual devices!
      Configuration
      789
      10 11 12
      123
      456
      13 14 15
      1
      2
      PWR CHK OUT
      S1
      S2
      S3
      123
      123
      S1
      S3
      II
      S2
      I
      Switch position
      Operating status
      Factory settings: switch 1, 2 and 3 in position I
      S Function Position
      1 Mode of operation
      Output I (relay)
      energized
      with high input current I
      with low input current II
      2 Mode of operation
      Output II (relay)
      energized
      with high input current I
      with low input current II
      3 Line fault detection ON I
      OFF II
      Control circuit Input signal
      Initiator high impedance/
      contact opened
      low input current
      Initiator low impedance/
      contact closed
      high input current
      Lead breakage,
      lead short-circuit
      Line fault
      Accessories
    在线询盘/留言
  • 0571-87774297