6XV1 83O-3EH1O产品细节
PROFIBUS FC 拖曳电缆, PROFIBUS 拖曳电缆,最多 加速度 4m/QS min. 3 每分钟百万次弯曲循环 2 芯弯曲半径约 120mm 有屏蔽,按米销售 供货单位最大 1000m 最小订货量 20m
|
SIDOOR ATD410W machine tool door drive
The SIDOOR ATD410W machine tool door drive can be used to operate horizontal sliding doors. The drive system has been specifically designed for use in a very wide range of machine tools. The communication-capable ATD410W controller offers complete flexibility for integration with a machine tool via the USS protocol (universal serial interface protocol).
The SIDOOR ATD410W machine tool door drive is an intelligent door control system that enables protective doors on machine tools to be opened and closed at adjustable speeds and accelerations.
The maintenance-free, variable speed drive unit comprises a DC motor with non-self-locking gearing.
Various motors are available for selection, they have to be ordered separately, see "Geared motors".
They must be ordered separately, see "Geared motors".
Operation of the door drive does not require limit switches. The door width and the "OPEN"/"CLOSE" positions are determined automatically.
The current operating states are indicated by a 7?segment display directly in the SIDOOR ATD410W machine tool door drive. They can also be displayed externally using the Software Kit or Service Tool, see "Additional units". The associated function block can be used for configuration and parameter assignment purposes, see "Programming".
Forces are transferred via a toothed belt, which passes over a deflector unit and can be fitted with two door clutch holders. The accessories are not included in the scope of supply, see "Accessories".
This enables handling of both one-sided and centrally opening doors.
Version |
Type |
See |
---|---|---|
Controller |
||
SIDOOR ATD410W machine tool door drive |
6FB1141?4AT10?3WE2 |
|
The following individual components must be ordered separately: |
||
Power supplies |
"Power supplies" |
|
|
6FB1112?0AT20?2TR0 |
|
|
6FB1112?0AT20?3PS0 |
|
Additional units |
"Additional units" |
|
|
6FB1105?0AT01?6SW0 |
|
|
6FB1105?0AT01?6ST0 |
|
|
6FB1115?0AT10?4CP0 |
|
DC geared motors |
"Geared motors" |
|
|
||
|
6FB1103?0AT14?4MB0 |
|
|
6FB1103?0AT13?4MB0 |
|
|
||
|
6FB1103?0AT14?3MC0 |
|
|
6FB1103?0AT13?3MC0 |
|
|
||
|
6FB1103?0AT10?4MB0 |
|
|
6FB1103?0AT11?4MB0 |
|
|
||
|
6FB1103?0AT10?3MC0 |
|
|
6FB1103?0AT11?3MC0 |
|
|
||
|
6FB1103?0AT10?3MD0 |
|
|
6FB1103?0AT11?3MD0 |
|
Accessories for the overall system |
"Accessories" |
|
|
||
|
6FB1104?0AT02?0AD0 |
|
|
6FB1104?0AT01?0AD0 |
|
|
||
|
6FB1104?0AT01?0AS0 |
|
|
6FB1104?0AT02?0AS0 |
|
|
6FB1144?0AT00?3AS0 |
|
|
||
|
6FB1104?0AT01?0CP0 |
|
|
6FB1104?0AT02?0CP0 |
|
|
6FB1104?0AT03?0AS0 |
|
|
||
|
|
|
|
|
|
Accessories for the SIDOOR ATD410W machine tool door drive only |
||
|
||
|
6FB1104?0AT00?0CB5 |
|
|
6FB1104?0AT01?0CB5 |
|
|
6FB1104?0AT05?0CB0 |
|
|
6FB1104?0AT07?0CB0 |
|
|
6FB1104?0AT10?0CB0 |
|
|
6FB1104?0AT15?0CB0 |
|
|
||
|
6GK1500?0FC10 |
|
|
6XV1830-0EH10 |
|
|
6ES7138?4DF11?0AB0 |
|
|
6ES7540?1AB00?0AA0 |
|
|
6ES7241?1CH32?0XB0 |
During initial commissioning, please note the following:
The SIDOOR ATD410W machine tool door drive is configured in STEP 7 or in the TIA Portal with the function block provided.
The Software Kit is available as an additional unit (see "Additional units") and allows quick and easy updating of the firmware using the Siemens HCS12 Firmware Loader.
User-friendly parameter setting and oscilloscope function is carried out via the SIDOOR User Software (part of the Software Kit).
All door parameters of the SIDOOR ATD410W machine tool door drive can be assigned via the PROFIDrive profile with the function block provided.
For details see "SIDOOR Door Control Systems AT40, ATD400K, ATD400S, ATD400V, ATD400W" Manual,http://support.automation.siemens.com/WW/view/en/58531074
Article number |
6FB1141-4AT10-3WE2 |
|
---|---|---|
SIDOOR ATD410W |
||
General information |
|
|
Product brand name |
SIDOOR |
|
Product version |
With USS interface |
|
Optional product expansion |
TRANSFORMER (6FB1112-0AT20-2TR0), NT40 (6FB1112-0AT20-3PS0), DIN rail holder (6FB1144-0AT00-3AS0) |
|
Manufacturer's article no. of the usable motor |
6FB1103-0AT11-3MC0, 6FB1103-0AT10-4MB0, 6FB1103-0AT10-3MC0, 6FB1103-0AT11-3MC0, 6FB1103-0AT14-3MC0, 6FB1103-0AT13-4MB0, 6FB1103-0AT14-4MB0, 6FB1103-0AT14-3MC0, 6FB1103-0AT13-3MC0, 6FB1103-0AT11-3MD0, 6FB1103-0AT10-3MD0 |
|
Manufacturer's article no. of the usable power supply unit |
6FB1112-0AT20-2TR0, 6FB1112-0AT20-3PS0, 6EP3446-8SB10-0AY0 |
|
Installation type/mounting |
|
|
Installation and mounting instructions |
No direct sunlight, requirements specific to the end application must be observed. NFPA industry environment: Installation outside a control cabinet only horizontal |
|
Supply voltage |
|
|
Rated value (DC) |
36 V |
|
Input current |
|
|
I2t, min. |
30 A2·s |
|
Power |
|
|
Active power input (standby mode) |
5 W |
|
Digital inputs |
|
|
Control inputs isolated |
Yes |
|
Control inputs p-switching |
Yes |
|
Protection in case of DC supply |
Use of a circuit breaker in the supply path according to 60898-1, 8A, C-characteristic type SIEMENS: 5SY4108-7 or 5SY4108-7KK11 |
|
Input voltage |
|
|
|
10 V; Observe polarity ! |
|
|
28 V; Observe polarity ! |
|
Input current |
|
|
|
9 mA |
|
|
27 mA |
|
Digital outputs |
|
|
short-circuit proof |
Yes |
|
Overload-proof |
Yes |
|
Remark |
Ensure correct polarity! CAUTION: Do not supply with external voltage! |
|
Output voltage |
|
|
|
24 V |
|
Output current |
|
|
|
400 mA |
|
Relay outputs |
|
|
Switching capacity of contacts |
|
|
|
0.01 A |
|
|
0.5 A |
|
Mechanical data |
|
|
Opening width of door, min. |
0.3 m |
|
Opening width of door, max. |
5 m |
|
Weight of door, max. |
600 kg |
|
Operating cycle frequency of door, max. |
180 1/h |
|
Counterforce, max. |
75 N |
|
Kinetic energy, max. |
100 J |
|
Interfaces |
|
|
Interfaces/bus type |
USS according to EIA 485, IEC 61800-7-200 Type 3 |
|
Number of bus nodes |
32 |
|
Isolation |
|
|
Overvoltage category |
2 |
|
Degree and class of protection |
|
|
IP degree of protection |
IP20 |
|
Standards, approvals, certificates |
|
|
Certificate of suitability according to EN 81 |
No |
|
CE mark |
Yes |
|
UL approval |
No |
|
EAC (formerly Gost-R) |
Yes |
|
TüV Inspectorate approval |
Yes |
|
China RoHS compliance |
Yes |
|
Standard for EMC |
EN 61000-6-2 / EN 61000-6-4 |
|
Standard for safety |
EN 60950-1 / EN ISO 13849-1 2008 Cat. 2 PL d |
|
Ambient conditions |
|
|
Ambient temperature during operation |
|
|
|
-20 °C |
|
|
50 °C |
|
Ambient temperature during storage/transportation |
|
|
|
-40 °C |
|
|
70 °C |
|
Air pressure acc. to IEC 60068-2-13 |
|
|
|
2 000 m |
|
Relative humidity |
|
|
|
10 % |
|
|
93 % |
|
Dimensions |
|
|
Width |
320 mm |
|
Height |
60 mm |
|
Depth |
80 mm |