Current requirement
At 24 V DC, max.
without taking account of digital outputs and DRIVE-CLiQ supply
|
0.8 A for CU305 incl. 350 mA for HTL encoder + 0.5 A for PM240?2 Power Module
|
Conductor cross-section, max.
|
2.5 mm2
|
Fuse protection, max.
|
20 A
|
Digital inputs
|
in accordance with IEC 61131?2 Type 1
3 isolated fail-safe inputs
5 isolated digital inputs
|
|
-3 ... +30 V
|
-
Low level (an open digital input is interpreted as "low")
|
-3 ... +5 V
|
|
15 ... 30 V
|
-
Current consumption at 24 V DC, typ.
|
6 mA
|
-
Delay time of digital inputs 1), approx.
|
|
|
15 μs
|
|
55 μs
|
-
Delay time of high-speed digital inputs 1), approx.
(high-speed digital inputs can be used for position detection)
|
|
|
5 μs
|
|
5 μs
|
-
Conductor cross-section, max.
|
1.5 mm2
|
Digital outputs
(continuously short-circuit-proof)
|
1 fail-safe digital output
4 bidirectional digital inputs/digital outputs, not isolated
|
|
24 V DC
|
-
Load current per digital output 2), max.
|
100 mA
|
|
150 μs
|
-
Conductor cross-section, max.
|
1.5 mm2
|
Analog input
|
-10 ... +10 V
Resolution 12 bits + sign
|
|
15 kΩ
|
Encoder evaluation
|
-
Incremental encoder TTL/HTL
-
SSI encoder without incremental signals
|
|
24 V DC/0.35 A or 5 V DC/0.35 A
|
-
Input current range TTL/HTL
|
2 ... 10 mA (typ. 5 mA)
|
|
500 kHz
|
|
100 ... 250 kBaud
depending on cable length
|
-
Resolution absolute position SSI
|
30 bit
|
|
|
|
100 m (328 ft)
(only bipolar signals permitted) 3)
|
|
100 m (328 ft) for unipolar signals
300 m (984 ft) for bipolar signals 3)
|
|
100 m (328 ft)
|
Power loss
|
<20 W
|
PE connection
|
M5 screw
|
Dimensions
|
|
|
73 mm (2.87 in)
|
|
|
|
195 mm (7.68 in)
|
|
183.2 mm (7.21 in)
|
|
|
|
71 mm (2.80 in)
|
|
55 mm (2.17 in)
|
Weight, approx.
|
0.95 kg (2.09 lb)
|
Certificate of suitability
|
cULus
|