西门子CPU416-3PN原装正品
西门子CPU416-3PN原装正品
产品价格:¥46(人民币)
  • 规格:完善
  • 发货地:上海松江
  • 品牌:
  • 最小起订量:1台
  • 免费会员
    会员级别:试用会员
    认证类型:企业认证
    企业证件:通过认证

    商铺名称:上海励辉自动化科技有限公司

    联系人:郭金秀(先生)

    联系手机:

    固定电话:

    企业邮箱:498588739@qq.com

    联系地址:上海市松江区广福林路4855弄19号4楼

    邮编:201616

    联系我时,请说是在焊材网上看到的,谢谢!

    商品详情

      CPU 416-3PN

      6ES7416-3ES07-0AB0

      SIMATIC S7-400, CPU 416-3 PN/DP CENTRAL PROCESSING UNIT WITH: 16 MB WORKING MEMORY, (8 MB KB CODE, 8 MB DATA), INTERFACES: 1. IF MPI/DP 12 MBIT/S (X1), 2. IF ETHERNET/PROFINET (X5), 3. IF IF964-DP PLUGABLE (IF1)

      SIPLUS S7-400 CPU 416-3 PN/DP -25 ... +70 摄氏度 带防腐蚀涂层 基于 6ES7416-3ES07-0AB0 。 中央处理器,带: 工作存储器 16 MB, (8 MB 代码,8 MB 数据), 接口 第 1 个 MPI/DP 接口 12 MBIT/S(X1), 第 2 个以太网/PROFINET 接口(X5) 第 3 个 IF 964-DP 接口可插拔(IF1)

      上海励辉自动化科技有限公司愿为您解答任何有关 SIEMENS 可编程控制器及变频器的技术问题,并提供详细的技术资料。公司还在某大型研究所内设有设施一流的培训中心,定期举办 S7 - 200/300 及变频器、全数字直流调速装置的技术培训班,为您尽快掌握 SIEMENS 自动化产品的使用提供便利。西门子PLC模块,西门子变频器,西门子触摸屏,西门子通讯电缆,西门子伺服驱动,西门子软启动器,西门子工控机,西门子交换机,自动化科技专业领域内的技术研发、技术服务,销售自动化控制设备、电气设备、五金交电、电子元器件、电子设备、仪器仪表、电线电缆、机电设备。
      本公司主要是通过电子商务经营大众消费品,消费品行业所有知名品牌产品等。本公司秉承“顾客至上,锐意进取”的经营理念,坚持“客户第一”的原则为广大客户提供优质的服务。欢迎广大客户惠顾!

      联系人:郭金秀
      24小时销售及维修热线:15216632215
      手 机:15216632215    Q  Q : 498588739
      邮箱:498588739@qq.com
      地址:上海市松江区广福林路4855弄19号4楼 


      概述

      • 高端性能范围内的高性能 CPU
      • 适用于对性能要求很高的工厂
      • CPU 416-3 PN/DP 中集成了 PROFINET 功能

      应用

      CPU 416-2, CPU 416-3 and CPU 416-3 PN/DP are powerful SIMATIC S7-400 CPUs.

      The integrated PROFIBUS DP interfaces in the CPU 416-2 and CPU 416-3 make it possible to connect directly to the PROFIBUS DP fieldbus as a master or slave.

      An additional DP master system can be connected to the CPU 416-3 and CPU 416-3 PN/DP using the IF 964-DP interface module.

      The integrated PROFINET interface of the CPU 416-3 PN/DP includes switch functionality when the ERTEC 400-ASIC is used. This forms the basis for providing two externally accessible PROFINET ports. In addition to hierarchical network topologies, this also enables the creation of line structures in the new S7-400 controllers.

      Note:
      Only the 6ES7 964-2AA04-0AB0 interface submodule may be used.

      设计

      Both CPUs are equipped with the following:

      • Powerful processor: 
        The CPUs achieve instruction execution times as low as 0.03 μs per binary instruction.
      • CPU 416-2: 5.6 MB RAM (of which 2.8 MB each for program and data); 
        CPU 416-3: 11.2 MB RAM (of which 5.6 MB each for program and data); 
        CPU 416-3 PN/DP: 11.2 MB RAM (of which 5.6 MB each for program and data); 
        fast RAM for parts of the user program relevant to execution.
      • Flexible expansion: 
        Up to 262144 digital and 16384 analog inputs/outputs.
      • Multi-point interface MPI: 
        With the MPI it is possible to establish simple networking of max. 32 stations at a data transmission rate of up to 12 Mbit/s. The CPUs can establish up to 44 connections to stations of the communications bus (C bus) and the MPI.
      • Mode selector switch: 
        Designed as toggle switch.
      • Diagnostics buffer: 
        The last 120 fault and interrupt events are retained in a ring buffer for diagnostic purposes. The number of entries can be parameterized.
      • Real-time clock: 
        The date and time are appended to diagnostic messages of the CPU.
      • Memory card: 
        For expansion of the integrated load memory. RAM and FEPROM cards (FEPROM for retentive storage) are available
      • Combined MPI/DP interface and integrated PROFIBUS DP interface (CPU 416-2 and CPU 416-3): 
        The PROFIBUS DP master interface allows a distributed automation configuration offering high speed and ease of use. From the user's point of view, the distributed I/O is treated as central I/O (same configuring, addressing and programming). 
        Mixed configuration: SIMATIC S5 and SIMATIC S7 as PROFIBUS master according to EN 50170.

      CPU 416-3 and CPU 416-3 PN/DP also include:

      • A module slot: 
        An additional PROFIBUS DP master system can be connected via the IF 964-DP interface module.

      CPU 416-3 PN/DP additionally includes:

      • PROFINET interface with 2 ports (switch):
        • PROFINET I/O, 256 IO devices connectable
        • PROFINET CBA

      功能

      • Block protection: 
        A password concept protects the user program from unauthorized access.
      • Integral HMI services: 
        The user only has to specify the source and destination of the data with HMI devices. The data are then transported cyclically and automatically by the system.
      • Integrated communications functions:
        • PG/OP communication
        • Shared data communication
        • S7 standard communication
        • S7 communication
      • Firmware update using network

      CPU 416-3 PN/DP additional:

      • Open communication over TCP/IP, UDP and ISO-on-TCP (RFC1006)
      • Distributed intelligence in Component Based Automation (CBA) on PROFINET
      • Additional diagnostic options with integrated web server
      Parameterizable attributes

      The STEP 7 tool "Hardware Configuration" can be used to program the properties and response of the S7-400 including the CPUs, e.g.

      • Multi-point interface MPI:
        • Definition of station addresses.
        • Startup/cycle behavior
        • Stipulation of the maximum cycle time and communications load
      • Address assignment: 
        Addressing of I/O modules.
      • Retentive ranges: 
        Definition of the number of retentive bit memories, counters, timers, data blocks and clock memories.
      • Size of the process image, local data.
      • Length of the diagnostics buffer
      • Protection level: 
        Definition of access authorization for program and data
      • System diagnostics: 
        Definition of the handling and scope of diagnostic messages
      • Timed interrupts: 
        Setting of periodicity

      CPU 416-3 PN/DP additional:

      • PROFINET interface
      • Parameterization of time synchronization using NTP procedure
      Indication and information functions
      • Status and error indicators: 
        LEDs indicate internal and external errors and operating states such as RUN, STOP, Restart, Test function, for example
      • Test functions: 
        The programming device can be used to display signal states in program execution, modify process tags irrespective of the user program, read out the contents of stack memories, run separate program steps and inhibit program components
      • Information functions: 
        The programming device can be used to provide the user with information on the memory capacity and operating mode of the CPU and the current utilization of the working and load memories

    在线询盘/留言
  • 0571-87774297