LDP63100-S
LDP63100-S
产品价格:¥1000(人民币)
  • 规格:LDP63100-S
  • 发货地:深圳
  • 品牌:
  • 最小起订量:1件
  • 诚信商家
    会员级别:钻石会员
    认证类型:企业认证
    企业证件:通过认证

    商铺名称:深圳市鑫博恒业科技有限公司

    联系人:李经理(小姐)

    联系手机:

    固定电话:

    企业邮箱:235521054@qq.com

    联系地址:深圳市福田区华强北路华强广场A栋17A(华强北地铁站-A口)

    邮编:518031

    联系我时,请说是在焊材网上看到的,谢谢!

    商品详情

      LDP63100-S详细介绍

      LDP63100-S

      1/8 DIN Universal Process Panel Meter with built-in USB
      DP63100

      Built-In USB Programming Port
      Modular Output Modules
      Universal Process, Voltage, Current, Resistance and Temperature Inputs
      Universal AC/DC Power Supply
      6/9 Digit Dual Line/ Tri-Color Display with 18 mm (0.71") and 8.9 mm (0.35")
      Programmable Units Display
      Variable Contrast and Intensity Display
      Up to 160 Samples Per Second Conversion Rate
      NEMA 4X (IP65) Sealed Front Bezel

      产品描述
      The DP63100 analog process panel meter offers many features and performance capabilities to suit a wide range of industrial applications. The DP63100 has a universal input to handle various input signals including DC voltage/current, process, resistance and temperature. The optional plug-in output cards allow the opportunity to configure the meter for present applications, while providing easy upgrades for future needs. The DP63100 employs a dual line, tri-color display with a large 18 mm (0.71"), tri-color 6 digit top display line and a 8.9 mm (0.35"), 9 digit green bottom display line. The meter provides a MAX and MIN reading memory with programmable capture time. The capture time is used to prevent detection of false max or min readings which may occur during start-up or unusual process events.The signal totalizer (integrator) can be used to compute a time-input product. This can be used to provide a readout of totalized flow or calculate service intervals of motors, pumps, etc.
      The meter has up to four setpoint outputs, implemented on plug-in option cards. The plug-in cards provide dual FORM-C relays, quad FORM-A, or either quad sinking or quad sourcing open collector logic outputs. The setpoint alarms can be configured to suit a variety of control and alarm requirements.
      Communication and bus capabilities are also available as option cards. These include RS232 and RS485. The DP63100 can be programmed to utilize MODBUS? protocol. With MODBUS, the user has access to most configuration parameters. Readout values and setpoint alarm values can be controlled through the bus. Additionally, the meter has a feature that allows a remote computer to directly control the outputs of the meter. The DP63100 includes a built-in USB programming port. With a Windows? based program, configuration data can be downloaded to the unit without the need of any additional option cards. A linear DC output signal is available as an optional plug-in card. The card provides either 20 mA or 10V signals. The output can be scaled independent of the input range and can track either the input, totalizer, max or min readings. The meter has been specifically designed for harsh industrial environments. With NEMA 4X (IP65) sealed bezel and extensive testing of noise effects and CE requirements, the meter provides a tough reliable application solution.

      SPECIFICATIONS
      Display: Negative image LCD
      Top Line: 6 digit, 18 mm (0.71"), with tri-color backlight (red, green or orange)
      Display Range: -199999 to 999999;
      Bottom Line: 9 digit, 8.9 mm (0.35"), with green backlight
      Display Range: -199,999,999 to 999,999,999
      Power
      AC Power: 50 to 250 Vac, 50/60 Hz, 14 VA
      DC Power: 21.6 to 250 Vdc, 8 W
      Isolation: 2300 Vrms for 1 min to all inputs and outputs. KEYPAD: 3 programmable function keys, 5 keys total
      A/D Converter: 24 bit resolution
      Update Rates: A/D conversion rate; programmable 5 to 160 readings/sec

      Thermocouple Inputs
      Readout:
      Scale: °F or °C
      Offset Range: -199,999 to 999,999 display units
      Input Impedance: 20 MO
      Lead Resistance Effect: 0.03 μV/Ω
      Max Continuous Overvoltage: 30V

      RTD Inputs
      Type: 3 or 4 wire, 2 wire can be compensated for lead wire resistance
      Excitation Current: 100 Ω
      Range: 136.5 μA ±10%
      10 Ω Range: 2.05 mA ±10%
      Lead Resistance: 100 Ω
      Range: 10 Ω/lead max
      10 Ω Range: 3 Ω/lead max
      Max Continuous Overload: 30V
      Excitation Power: Jumper selectable
      Transmitter Power: ±18 Vdc @ 50 mA
      Reference Voltage: ±2 Vdc, ±2%

      User Inputs
      Two Programmable User Inputs Max Continuous Input: 30 Vdc
      Isolation to Sensor Input Common: Not isolated
      Response Time: 12 msec max

      Totalizer
      Time Base: Second, minute, hour, or day
      Batch: Can accumulate (gate) input display from a user input
      Time Accuracy: 0.01% typical
      Decimal Point: 0 to 0.0000
      Scale Factor: 0.001 to 65.000
      Low Signal Cut-Out: -199,999 to 999,999
      Total: 6 digits on line 1; 9 digits on line 2

      Custom Linearization
      Data Point Pairs: Selectable from 2 to 16
      Display Range: -199,999 to 999,999
      Decimal Point: 0 to 0.0000
      Memory: Nonvolatile FRAM memory retains all programmable parameters and display values

      Environmental Conditions
      Operating Temperature Range: 0 to 50°C (32 to 122°F) 0 to 45°C (32 to 113°F) with all three plug-in cards installed
      Storage Temperature Range: -40 to 60°C (-40 to 140°F)
      Operating and Storage Humidity: 0 to 85% max RH non-condensing
      Altitude: Up to 2000 m (6561')
      Connections: High compression age-clamp terminal block
      Construction: This unit is rated for NEMA 4X (IP65) outdoor use IP20 touch safe. Installation Category II, pollution degree 2. One piece bezel/case. Flame resistant. Synthetic rubber keypad. Panel gasket and mounting clip included.
      Dimensions
      Case: 44.45 H x 91.44 W x 105 mm D (1.75 x 3.6 x 4.14")
      Bezel: 49.53 x 96.52 mm (1.95 x 3.8")
      Panel Cutout: 1/8 DIN, 45 x 92 mm (1.77 x 3.62")
      Weight: 226.8 g (8 oz)

      注: Comes complete with operator’s manual.
      Adding option cards to meters can be fitted with up to three optional plug-in cards. However, only one card from each function type can be installed at a time. The function types include Setpoint Alarms, Communications, and Analog Output. The cards can be installed initially or at a later date. Each optional plug-in card is shipped with installation and programming instructions.

      产品编号   产品描述

      DP63100   1/8 DIN universal process panel meter

      Accessories

      LDP6-CDS10  Dual setpoint relay output card

      LDP6-CDS20  Quad setpoint relay output card
        
      LDP6-CDS30  Quad setpoint sinking open collector output card

      LDP6-CDS40   Quad setpoint sourcing open collector output card

      LDP6-CDL10  Analog output card
        
      LDP6-CDC10  RS485 serial communications output card with terminal block
        
      LDP6-CDC1C   Extended RS485 serial communications output card with dual RJ11 connector
        
      LDP6-CDC20   RS232 serial communications output card with terminal block
        
      LDP6-CDC2C   Extended RS232 serial communications output card with 9 pin D connector
       

      产品编号 
      DP63100  

      LDP6-CDS10
      LDP6-CDS20 
      LDP6-CDS30 
      LDP6-CDS40 
      LDP6-CDL10
      LDP6-CDC10 
      LDP6-CDC1C  
      LDP6-CDC20 
      LDP6-CDC2C  

       LDP63100-S


      LDP63100-S 相关产品

      LDP63100-S 技术文章

    在线询盘/留言
  • 0571-87774297