LDP6-CDC20
LDP6-CDC20
产品价格:¥1000(人民币)
  • 规格:LDP6-CDC20
  • 发货地:深圳
  • 品牌:
  • 最小起订量:1件
  • 诚信商家
    会员级别:钻石会员
    认证类型:企业认证
    企业证件:通过认证

    商铺名称:深圳市鑫博恒业科技有限公司

    联系人:李经理(小姐)

    联系手机:

    固定电话:

    企业邮箱:235521054@qq.com

    联系地址:深圳市福田区华强北路华强广场A栋17A(华强北地铁站-A口)

    邮编:518031

    联系我时,请说是在焊材网上看到的,谢谢!

    商品详情

      LDP6-CDC20详细介绍

      LDP6-CDC20
      Large Display Meter for Digital Input
      LDPF63000

      Large Led Display Readable to 21 m (70')
      Digital Input Module; Count and Rate Input Serial Slave
      Alarms, Analog Output, and Communication
      Programmable User Inputs
      Programmable Function Keys
      PC Software for Meter Configuration
      NEMA 4 (IP65)

      产品描述
      The LDPF63000 Display is a versatile display that can increase productivity by offering the plant floor or production area a large visual display of their current status. Whether your measurement is rate or count, the LDPF63000 can satisfy your requirement. These LDPF63000 displays accept various digital inputs through the use of input modules that allow the unit to adapt to most any application. Additional plug-in option cards can add alarms, analog output, and communication/bus capabilities, making the LDPF63000 a truly intelligent panel meter.

      SPECIFICATIONS
      Rate Display
      Accuracy: ±0.01%
      Min Frequency: 0.01 hz
      Max Frequency: see max signal frequencies table
      Max Display:
      5 Digits: 99999 Adjustable Display (Low) Update: 0.1 to 99.9 seconds Counter Displays
      Maximum Display:
      8 Digits: ± 99999999 (greater than 6 digits display alternates between high order and low order)
      Inputs A and B
      DIP switch selectable to accept pulses from a variety of sources including switch contacts, TTL outputs, magnetic pickups and all standard sensors.
      Logic: Input trigger levels VIL = 1.5V max; VIH = 3.75V min
      Current Sinking: Internal 7.8 K pull-up to 12 Vdc, IMAX = 1.9 mA
      Current Sourcing: Internal 3.9 K pull-down, 7.3 mA max @ 28 Vdc, VMAX = 30 Vdc
      Filter: Damping capacitor provided for switch contact bounce. Limits input frequency to 50 hz and input pulse widths to 10 msec minimum
      Magnetic Pickup
      Sensitivity: 200 mV peak
      Hysteresis: 100 mV
      Input Impedance: 3.9 K @ 60 hz
      Max Input Voltage: ±40V peak, 30 Vrms
      Dual Count Modes: When any dual count mode is used, then user inputs 1 and/or 2 will accept the second signal of each signal pair. The user inputs do not have the Logic/Mag, High/Low Freq, and Sink/Source input setup switches. The user inputs are inherently a logic input with no low frequency filtering. Any mechanical contacts used for these inputs in a dual count mode must be debounced externally. The user input may only be selected for sink/source by the user jumper placement.
      Prescaler Output
      NPN Open Collector: ISNK = 100 mA max @ VOL = 1 Vdc max VOH = 30 Vdc max with duty cycle of 25% min and 50% max
      Display: 38 mm (1.5") red LED
      Power (AC Modules): 85 to 250 Vac, 50/60 hz, 18 VA
      Annunciators: A, B, C, SP1, SP2, SP3, and SP4
      Keypad: Five tactile membrane switches integrated into the front panel
      Enviromental Conditions
      Operating Temperature Range: 0 to 45°C (32 to 113°F)
      Storage Temperature Range: -40 to 60°C (-40 to 15°F) Operating and Storage Humidity: 0 to 85% max RH (non-condensing)
      Altitude: Up to 2000 m (6562')
      Mounting Requirements
      Max panel thickness is 9.5 mm (0.375") Min panel thickness for NEMA 4 (IP65) sealing is 1.57 mm (0.060")
      Connections: All wiring connections are made to the module via high compression cage-clamp terminal blocks. Wiring instructions are provided.
      Construction: Steel front panel, enclosure, and rear cover with textured black polyurethane paint for scratch and corrosion resistance protection. Sealed front panel meets NEMA 4 (IP65) specifications for indoor use when properly installed. Installation Category II, Pollution Degree II. Panel gasket and keps nuts included.
      Weight: 1.2 kg (2.7 lbs) (less module)

      OPTION BOARDS SPECIFICATIONS
      RS485 Communication Card:(LDP6-CDC10 or LDP6-CDC1C)
      Type: RS485 multi-point balanced interface Isolation to Sensor and User
      Input Commons: 500 Vrms for 1 min
      Working Voltage: 50V not isolated from all other commons
      Baud Rate: 300 to 19.2k
      Data Format: 7/8 bits; odd, even, or no parity
      Bus Address: 0 to 99, max 32 meters per line
      Transmit Delay: Selectable 2 to 50 msec or 50 to 100 msec
      RS232 Communication Card (LDP6-CDC20 or LDP6-CDC2C)
      Type: RS232 half duplex Isolation to Sensor and User
      Input Commons: 500 Vrms for 1 min
      Working Voltage: 50V not Isolated from all other commons
      Baud Rate: 300 to 19.2k
      Data Format: 7/8 bits; odd, even or no parity
      Modbus Communications Card (LDP6-CDC40 or LDP6-CDC4C)
      Type: RS485; RTU and ASCII MODBUS modes Isolation to Sensor and User Input
      Commons: 500 Vrms for 1 minute
      Working Voltage: 50V not isolated from all other commons
      Baud Rates: 300 to 38400
      Data: 7/8 bits
      Parity: No, odd, or even
      Addresses: 1 to 247
      Analog Output Card (LDP6-CDL)
      Types: 0 to 20 mA, 4 to 20 mA and 0 to 10 Vdc Isolation to Sensor and User Input
      Commons: 500 Vrms for 1 min
      Working Voltage: 50V not isolated from all other commons
      Accuracy: 0.17% of FS (18 to 28°C); 0.4% of FS (0 to 50°C)
      Resolution: 1/3500
      Compliance:
      10 Vdc: 10 KΩ load min
      20 mA: 500 Ω load max
      Update Time: 200 msec max to within 99% of final readout value (digital filter and internal zero correction disabled) 700 msec max (digital filter disabled, internal zero correction enabled)
      LDP63000-AC: 1 sec max to within 99% of final readout value (digital filter disabled)
      Setpoint Output Cards (Four Types of Field Installable Cards)
      Response Time: 200 msec max to within 99% of final readout value (digital filter and internal zero correction disabled)700 msec max (digital filter disabled, internal zero correction enabled)
      LDP63000-AC Only: 1s max to within 99% of final readout value (digital filter disabled)
      LDP63000-T Only: 200 msec typ.; 700 msec max (digital filter disabled)
      Dual Relay Card (LDP6-CDS10)
      Type: Two FORM-C relays Isolation to Sensor and User Input
      Commons: 2000 Vrms for 1 min
      Working Voltage: 250V
      Contact Rating:
      One Relay Energized: 5 Amps @ 120/240 Vac or 28 Vdc (resistive load), 1.8 HP @120 Vac, inductive load total current with both relays energized not to exceed 5 Amps
      Life Expectancy: 100K cycles min at full load rating. External RC snubber extends relay life for operation with inductive loads.
      Quad Relay Card (LDP6-CDS20)
      Type: Four FORM-A relays Isolation to Sensor and User Input
      Commons: 2300 Vrms for 1 min
      Working Voltage: 250 Vrms
      Contact Rating:
      One Relay Energized: 3 Amps @ 250 Vac or 30 Vdc (resistive load), 1.10 HP @120 Vac, inductive load total current with all four relays energized not to exceed 4 Amps
      Life Expectancy: 100K cycles min at full load rating. External RC snubber extends relay life for operation with inductive loads.
      Quad Sinking Open Collector (LDP6-CDS30)
      Type: Four isolated sinking NPN transistors Isolation to Sensor and User
      Input Commons: 500 Vrms for 1 min
      Working Voltage: 50V not isolated from all other commons
      Rating: 100 mA max @ VSAT = 0.7V max Vmax = 30V Quad Sourcing Open Collector (LDP6-CDS40)
      Type: Four isolated sourcing PNP transistors Isolation to Sensor and User
      Input Commons: 500 Vrms for 1 min
      Working Voltage: 50V not isolated from all other commons
      Rating:
      Internal Supply: 24 Vdc ±10%, 30 mA max total all four
      External Supply: 30 Vdc max, 100 mA max each output
      Programming Software
      (Free download) Allows configuration of the LDPF63000 meter from a PC. This software offers standard drop-down menu commands, that make it easy to program the meter. The unit program can then be saved in a PC file for future use. A serial plug-in card is required to program the meter using the software.


      产品编号 产品描述

        
      LDPF63000 Large display meter, digital inputs, 85 to 250 Vac power


      Setpoint Alarms (Only 1 Alarm Card Can Be Installed Into Base Meter)

      LDP6-CDS10 Dual setpoint relay output card

      LDP6-CDS20 Quad setpoint relay output card
        
      LDP6-CDS30 Quad setpoint sinking open collector output card

      LDP6-CDS40 Quad setpoint sourcing open collector output card

      Analog Output

      LDP6-CDL10 Analog output card

      Communications (Only 1 Communications Card Can Be Installed Into Base Meter)
        
      LDP6-CDC10 RS485 serial communications output card with terminal block
        
      LDP6-CDC1C Extended RS485 serial communications output card with dual RJ11 connector
        
      LDP6-CDC20 RS232 serial communications output card with terminal block
       
      LDP6-CDC2C Extended RS232 serial communications output card with 9-pin D connector
       
      LDP6-CDC40 MODBUS? communications card
       
      LDP6-CDC4C Extended MODBUS? communications card with dual RJ11 connector

      Accessories
        
      LDP6-PGM Remote programming module with 3 m (10') cable

      LDP6-ENC12 NEMA 4 (IP65) enclosure
        
      LDP631-SHR Shroud
        
      LDP6-EN/SH NEMA 4 (IP65) enclosure with shroud


       LDP6-CDC20


      LDP6-CDC20 相关产品

      LDP6-CDC20 技术文章

    在线询盘/留言
  • 0571-87774297