QuadTech is discontinuing it's 7000 LCR Precision LCR Meter Series. Limited quantities are still available. Call today for more information. QuadTech's new 7600 Plus Precision LCR Meter replaces the 7000 Series.
Description
Automatic Test Sequencing: Run up to six different tests in sequence with a single push of the start button. Each test can have different test conditions and limits.
Swept Measurements: Fast and accurate swept parameter measurements, graphical or tabular, for verification of component and material response to changes in ac test frequency, ac test voltage or ac test current, without the need for complex programming or an external controller.
Program and Data Storage: Test setups can be stored and recalled either from internal memory or from standard DOS formatted 3 1/2" floppy disks. The front panel controls can be locked out, with password protection, to insure procedures are run the same way every time. Measured data can be stored on a floppy disk and then transferred to PC for data reduction and analysis.
Load Correction: Substantially improves instrument accuracy by performing measurements on a known standard and applying the correction to subsequent measurements. Ideal for repetitive testing of identical devices at like test conditions.
Automatic Calibration Procedure: The 7000 can be calibrated without returning the unit to the factory using the NIST traceable QuadTech Calibration Kit, reducing down time and calibration costs.
Easy to Use: Large LCD graphics display and user friendly menu driven interface allows the 7000 to be put on line quickly, providing useful measurements by operators with little to no training. The 3 ½” disk drive allows for transfer of test results to PC for data analysis.
Why Buy?
The widest possible frequency range (7600 to 2MHz, 7400 to 500kHz)
The graphical sweep function of Z vs. frequency, voltage or current
A lower cost alternative to the Agilent Model 4284A
Features
Measures 14 Impedance Parameters (2 simultaneously)
0.05% Basic Measurement Accuracy
289,900 Programmable Frequencies from 10Hz to 2MHz
AC Test Voltage Programmable from 20mV to 5V
DC Bias Voltage, 2V Internal or 0 to 200V External
Fast Measurement Speeds up to 40/Second
Automatic Open/Short Zeroing Eliminates Connection Errors
High Resolution LCD with 7 Digit Display
14 Hi/Lo Sorting Bins for Pass/Fail Testing
RS-232, IEEE-488, Printer, and PLC Interfaces all Standard
Results Displayed as Deviation or %Deviation from a Nominal Value
Internal Storage and Recall of Test Setups
Constant Voltage Maintained to the Device Under Test
Ability to Automatically Perform 6 Unique Tests in Sequence
Keypad Lockout Prevents Changes to the Test Setup
On site calibration with NIST Traceable Cal Kit
Programmable Average and Delay Times