P-6501-4007 SFC050A-4517福州天行健17年专业提供德国原装novotechnik船用电位器,原装novotechnik旋转传感器现货
Novotechnik introduced potentiometers to general mechanical engineering in the 1950s.
Type P/N :P-6501-4007 008218
Mechanical Data
Dimensions see drawing
Mounting with 3 clamps Z-1-31
Mechanical travel 360, continuous °
Permitted shaft loading (axial and radial)
static or dynamic force
45 N
Torque < 0.25 Ncm
Maximum operational speed 10 000 min-1
Weight 80 g
Electrical Data
Actual electrical travel 2 x 178 °
Def. electrical range 2 x 100
(±50° to electrical center within
electrical range)
Available eresistance values 2.5 kΩ
Resistance tolerance ±20 %
Repeatability 0.002 ( 0.007°) %
Temperature coefficient
of the output-to-applied voltage ratio
typ. 5 ppm/K
Type P/N:P-2501-120-285-001 (angle 120°, 2-section) 003266*
Type P/N:P-2501-240-286-001 (angle 240°, 2-section) 003267*
Type P/N:P-2501-345-253-001 (angle 345°, 2-section) 003268
Type P/N:P-2501-120-385-001 (angle 120°, 3-section) 003263*
Type P/N:P-2501-240-386-001 (angle 240°, 3-section) 003264*
Type P/N:P-2501-345-353-001 (angle 345°, 3-section) 003265
Mechanical Data
Dimensions see dimension drawing
Mounting clamp with 2 cylinder screws M4x10
Mechanical travel 360 continous °
Permitted shaft loading (axial and radial)
static or dynamic force
15 N
Torque < 1.5 Ncm
Maximum operational speed 2,000 RPM
Weight 24 (2 sections) / 31 (3 sections) g
Electrical Data
Measuring range (dimension L) 120 ±2 240 ±2 345 ±2 °
Defined electrical range 114 234 339 °
Nominal resistance 1 2 5 kΩ
Resistance tolerance 20 ±%
Independent linearity 0.3 ±%FS
Repeatability 0.01 °
Interlinearity 1 ±%FS
Maximum permissible applied voltage 42 VDC
Recommended wiper operating current ≤ 1 μA
Maximum wiper current in case of mulfunction max. 10 mA
Effective temperature coefficient
of the output-to-applied voltage ratio
typ. 5 ppm/K
Insulation resistance (500 VDC) ≥ 10 MΩ
Dielectric strength (500 VAC, 50 Hz) ≤ 100 μA
Environmental Data
Temperature range -40 … +100 °C
Vibration (IEC 60068-2-6) 5….2000
Amax = 0.75
amax = 20
Hz
mm
g
Shock (IEC 60068-2-27) 50 (11 ms) g
Life 50x106 movements
Functional safety When using our products in safety-related systems, please contact us.
Protection class (DIN 40050 / IEC 529) IP40